Engineer A Written Third-Party Safety Notification Building Owners
O · Obligation
Individual
http://proethica.org/ontology/case/132#Engineer_A_Written_Third-Party_Safety_Notification_Building_Owners
Properties
Instance of
WrittenThird-PartySafetyNotificationObligation
http://proethica.org/ontology/intermediate#WrittenThird-PartySafetyNotificationObligation
Case context
Engineer A verbally recommended to the building owners that they brace the building to prevent collapse; the case does not indicate that this recommendation was made in writing.
Compliance status
unmet
Confidence
0.89
Importance
high
Obligated party
Engineer A
Obligation statement
Engineer A was obligated to notify the building owners in writing about the structural deficiency — in addition to any verbal recommendation to brace the building — so that the affected parties had a documented record of the risk and could take informed protective action.
Temporal scope
Upon identification of structural instability and recommendation to building owners
Relationships
defeasibleUnder
County Building Official Non-Response to Safety Notification
derivedFromPrinciple
Written Documentation Requirement Implicated By Engineer A Phone Call
Source Evidence
Source text
Engineer A also recommended to the owners to brace the building to prevent its collapse.
Text references
Engineer A also recommended to the owners to brace the building to prevent its collapse.
TTL
@prefix case132: <http://proethica.org/ontology/case/132#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix proeth: <http://proethica.org/ontology/intermediate#> .
@prefix proeth-core: <http://proethica.org/ontology/core#> .
@prefix prov: <http://www.w3.org/ns/prov#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
case132:Engineer_A_Written_Third-Party_Safety_Notification_Building_Owners a proeth:WrittenThird-PartySafetyNotificationObligation,
owl:NamedIndividual ;
rdfs:label "Engineer A Written Third-Party Safety Notification Building Owners" ;
proeth-core:defeasibleUnder case132:County_Building_Official_Non-Response_to_Safety_Notification ;
proeth:casecontext "Engineer A verbally recommended to the building owners that they brace the building to prevent collapse; the case does not indicate that this recommendation was made in writing." ;
proeth:compliancestatus "unmet" ;
proeth:conceptCategory "Obligation" ;
proeth:confidence "0.89" ;
proeth:derivedFromPrinciple case132:Written_Documentation_Requirement_Implicated_By_Engineer_A_Phone_Call ;
proeth:discoveredincase "132" ;
proeth:discoveredinpass "2" ;
proeth:discoveredinsection "facts" ;
proeth:firstdiscoveredat "2026-02-27T18:00:00.019063+00:00" ;
proeth:firstdiscoveredincase "132" ;
proeth:generatedattime "2026-02-27T18:00:00.019063+00:00" ;
proeth:importance "high" ;
proeth:obligatedparty "Engineer A" ;
proeth:obligationclass "Written Third-Party Safety Notification Obligation" ;
proeth:obligationstatement "Engineer A was obligated to notify the building owners in writing about the structural deficiency — in addition to any verbal recommendation to brace the building — so that the affected parties had a documented record of the risk and could take informed protective action." ;
proeth:sourcetext "Engineer A also recommended to the owners to brace the building to prevent its collapse." ;
proeth:temporalscope "Upon identification of structural instability and recommendation to building owners" ;
proeth:textreferences "Engineer A also recommended to the owners to brace the building to prevent its collapse." ;
proeth:wasattributedto "Case 132 Extraction" ;
prov:generatedAtTime "2026-02-27T18:17:34.023811"^^xsd:dateTime ;
prov:wasGeneratedBy "ProEthica Case 132 Extraction" .
Metadata
Extraction details
Discovered in case
132
Discovered in pass
2
Discovered in section
facts
First discovered
2026-02-27T18:00:00.019063+00:00
First case
132
Generated
2026-02-27T18:00:00.019063+00:00
Attributed to
Case 132 Extraction
Generated
2026-02-27T18:17:34.023811
Generated by
ProEthica Case 132 Extraction